We monitor the links using SNMP, Simple Network Management Protocol, data. In order to capture the SNMP data we only need IP access to the terminal via a public IP address or a VPN, and the Read SNMP Community string, typically "public".
The most informative SNMP variables and alarm limits
Vubiq RF DSSI
OID: 1.3.6.1.4.1.46330.2.2.1.7.0
Digital signal strength indicator from 0 (no signal) to 100 (perfect signal). Integer32 (0..100), Read Only.
Vubiq recommends: Warning limit: below 90%. Error limit: below 50%.
Vubiq RF Board Temp
OID: 1.3.6.1.4.1.46330.2.2.1.15.0
Board temperature in °C. Integer32, Read Only.
Vubiq recommends: Warning limit: above 80 °C. Error limit: above 85 °C.
Vubiq RF TX Temp
OID: 1.3.6.1.4.1.46330.2.2.1.16.0
Transmit module temperature in °C. Integer32, Read Only.
Vubiq recommends: Warning limit: above 70 °C. Error limit: above 80 °C.
Vubiq RF RX Temp
OID: 1.3.6.1.4.1.46330.2.2.1.17.0
Receiver module temperature in °C. Integer32, Read Only.
Vubiq recommends: Warning limit: above 70 °C. Error limit: above 80 °C.
Vubiq RF Board Uptime
OID: 1.3.6.1.4.1.46330.2.2.1.19.0
The number of seconds since the unit was powered on. Basically, (sysUpTime * 100). Integer32, Read Only.
Vubiq recommends: Warning limit: below 300 seconds.
Vubiq RF RX FEC Errors
OID: 1.3.6.1.4.1.46330.2.2.1.23.0
The raw FEC correctable error counts. Counter32, Read Only.
Vubiq recommends: Trend over time to detect link degradation.
To have your terminal's performance monitored and tracked, or for more information about Vubiq's SNMP data, please contact us.