Blog · October 2017 · Michael Klett

V60s Field Link Monitoring

A service that Vubiq Networks offers our customers is performance monitoring of our links out in the field.

We monitor the links using SNMP, Simple Network Management Protocol, data. In order to capture the SNMP data we only need IP access to the terminal via a public IP address or a VPN, and the Read SNMP Community string, typically "public".

The most informative SNMP variables and alarm limits

Vubiq RF DSSI

OID: 1.3.6.1.4.1.46330.2.2.1.7.0

Digital signal strength indicator from 0 (no signal) to 100 (perfect signal). Integer32 (0..100), Read Only.

Vubiq recommends: Warning limit: below 90%. Error limit: below 50%.

Vubiq RF Board Temp

OID: 1.3.6.1.4.1.46330.2.2.1.15.0

Board temperature in °C. Integer32, Read Only.

Vubiq recommends: Warning limit: above 80 °C. Error limit: above 85 °C.

Vubiq RF TX Temp

OID: 1.3.6.1.4.1.46330.2.2.1.16.0

Transmit module temperature in °C. Integer32, Read Only.

Vubiq recommends: Warning limit: above 70 °C. Error limit: above 80 °C.

Vubiq RF RX Temp

OID: 1.3.6.1.4.1.46330.2.2.1.17.0

Receiver module temperature in °C. Integer32, Read Only.

Vubiq recommends: Warning limit: above 70 °C. Error limit: above 80 °C.

Vubiq RF Board Uptime

OID: 1.3.6.1.4.1.46330.2.2.1.19.0

The number of seconds since the unit was powered on. Basically, (sysUpTime * 100). Integer32, Read Only.

Vubiq recommends: Warning limit: below 300 seconds.

Vubiq RF RX FEC Errors

OID: 1.3.6.1.4.1.46330.2.2.1.23.0

The raw FEC correctable error counts. Counter32, Read Only.

Vubiq recommends: Trend over time to detect link degradation.

To have your terminal's performance monitored and tracked, or for more information about Vubiq's SNMP data, please contact us.

← Back to the blog

Want your links monitored?

Vubiq Networks can track DSSI, temperature and FEC performance on your deployed millimeter wave links.